Equipment maintenance method statement

UV machine on maintenance

  1. Cleaning surface dust and maintain the body clean.

  2. To start the machinery to check fans, motor functioning and whether it is normal, with or without abnormal noise, if the immediate closure of the machine to inform the maintenance overhaul. 3. Turn on the lights after the UV lamp to check whether it has been lit, and if there are not lit, and notify the maintenance overhaul.

 

  On maintenance

  1. To check whether the plug vents, and clean up dust.

  2. Inspection lamp current and whether it is normal, whether the aging lines.

  3. Inspection fan motor is running normally, motor is able to meet the job requirements.

  4. Refueling transmission chain, sprocket refueling. 5. UV lamp's light intensity is also to meet work standards, whether the lamp aging.

  6. Cavity cleaning dust.

 

  Half-yearly maintenance

  1. Inspection lines and switches are normal.

  2. Refueling motor gearbox.

  3. Transformer insulation of not less than 5 megohm, if not, we must re-dry transformer.

  4. Reflectors with a soft clean rags Zhanhua alcohol. 5. Propshafts, whether loose sprocket, the two sprocket is vertical. 6. Mesh belt tightness is appropriate.

 

  Oven on maintenance

  1. Cleaning the surface and intracavity dust and maintain the machines clean and healthy.

  2. Inspection ammeter current with the same way as normal, if unusual, notify the maintenance overhaul.

  3. A sudden power outage, it is necessary to turn off the heating switch to prevent the calls automatically activated. 4. To check whether it is normal for fan operation, with or without abnormal noise, if the immediate closure of the machine and notify the maintenance overhaul.

 

  On maintenance

  1. To check whether the plug vents, and clean up dust.

  2. Blower operation are normal.

  3. Maintenance check whether current normal.

  4. To check the accuracy of temperature control device, such as inaccurate, please adjust the thermostat or sensor static compensation amendment value.

  5. To check the availability of heating pipe damage, whether or not the aging lines.

  6. To check the accuracy of delay devices, whether or not to allow errors.

 

 

  Plate on maintenance

  1. Cleaning dust and maintain the machines clean.

  2. Check whether the normal fan operation, with or without abnormal noise, if the immediate closure of the machine and notify the maintenance overhaul.

 

  On maintenance

 

  1. Inspection vacuum cooling oil is adequate, and whether the turbid dirty, if not enough cooling oil or dirty, it is necessary to immediately increase the cooling oil replacement.

  2. Check the accuracy of delay devices, whether or not to allow errors.

  3. Inspection lines, switches and whether it is normal, whether or not the aging lines.

  4. UV lamp's light intensity is also to meet work standards, whether the lamp aging.

  5. Transformer insulation of not less than 5 megohm, if not, we must re-dry transformer.

 

  IR heaters on maintenance

  1. Cavity surface and dust cleaning, maintaining the body clean and healthy.

  2. Check the speed of warming and whether it is normal, compared with the past, if there is abnormal, informing maintenance overhaul.

  3. To check the electrical functioning of normal, with or without abnormal sounds, if there is immediately shut down the machine, notify the maintenance overhaul.

 

  On maintenance

  1. To check whether the plug vents.

  2. Maintenance check whether current normal.

  3. To check the accuracy of temperature controller. If not accurate, please adjust the thermostat or sensor static compensation amendment value.

  4. To check the availability of heating pipe damage, whether or not the aging lines.

  5. To check whether the electrical functioning of normal speed for accuracy.

  6. Refueling transmission chain, sprocket refueling.

 

 

  Half-yearly maintenance

  1 Check the switches and circuits are in working order, with or without aging.

  2 motor gearbox refueling.

  3 shaft, the availability of loose sprocket, the two sprocket is vertical.

  4 mesh belt tightness is appropriate.

author: Chenbro electronic      Published at: 2008-6-19 1:40:24