Chemical formula designer

UV curing equipment curing system designers the choice of many recipes in their test only the use of QC UV curing equipment, instead of using other equipment, it is because our equipment can simulate any curing conditions. May be a more important reason is that in your use of the laboratory UV curing system exactly is your customer's package needed for the production line system.

 

 Therefore, in the laboratory to complete your research results can be directly translated into productivity. QC is simple to use UV curing system fully functional, easy to use

   Formula based on your needs, you can easily replace the lamp spectral range. Just five minutes, you can put on five criteria QC any one lamp.

   You can turn on or turn off the system at any time. Only 5-7 seconds, the system can achieve the rated output state, when you can start production. Now, you do not need to produce only a few samples and was driving a machine all day.

   If you need to reduce system heat, simply insert a dichroic mirror can.

   If you want from a fully focused entirely focused non-state transition state, so that wider focus, we have a mirror, you can use it to focus. Choice of curing room or choose delivery device? If your customers are very likely to be using dynamic curing, then choose delivery devices. However, if they may use static curing, then select curing room. Under normal circumstances, the design of the reaction formula is relatively slow (more than 1 seconds curing time), the curing conditions will choose low degree of long exposure. This type of formula often changing the site-based processing has been used, such as the use of UV adhesive bonding. Curing Room can provide you with long exposure and low degree of curing conditions. Rapid reaction formula tend to choose high-speed continuous conveyor installations, so if you formula in response to fast, they should be installed in the laboratory such a transmission device. QC UV can provide laboratory equipment

 Curing Room

 

 Desktop delivery device

 Block land-transfer device

 UV curing system - used in the above facilities (detailed information please see the Products part) □ How do I set up as a condition of UV curing equipment suppliers, often there will be some end-users and designers to the formula we asked what kind of UV curing technology to curing their formula, but the specific formula that they would not tell us or any related personnel. The following are those we are "curing technology" examples. Do not know if you can guess what went wrong, or what it omitted. Incomplete technical conditions &

 "200 watts / inch," "10 feet / minute," "gallium Light"

 

 "25 J / square cm," "mercury" "7 seconds" "120 watts / cm, H-type tubes" If you have been used in the past or now being used in the technical conditions with the curing similar to the technical conditions, please do not feel embarrassed. Here we will explain you how simple to fix your technical requirements. Whether it is curable coatings or ink or binder, any one of the conditions of UV curing technology should include the parameters of the surface flux, but also what "color" as well as the long exposure. For UV curing technology, the concrete form of the above parameters as follows: 1. Radiosity, Watt / cm2 refers to the output of ultraviolet light radiation flux density. It can be easily input power with the UV lamp confused input power unit is the watt / inch or watts / cm. Radiometer can be measured using radiosity. Because of measuring radiation differently, so you need to specify the use of the type of radiation. 2. Spectral distribution, nanometer range, or UVA, UVB, UVC and UVV band help to determine the parameters and curing matched the type of UV lamps. Spectral distribution of the choice depends on the formula used Photoinitiators type and initiator of light absorption rate. Most radiometric survey of the office is a band-band or a few degrees to the radiation. Therefore, the best in your report that in your formula measured in the smallest degree of radiation or energy, and in each band have carried out radiation measurement, and only this can guarantee the full curing. In addition, please specify your used UV lamp types (such as H, D or V-), it also helps us to diagnosis. At the very least, you should also be listed in both UVA and UVC-band radiation degrees. 3. Exposure time, the number of seconds formula needs time to curing? Curing type - static or dynamic, determined that the arrangement of light program, and the arrangement of light you need to ensure that the object can receive adequate radiosity. Requires you to report the data is the object of the minimum required for full curing time, curing for static need to report that curing time (in seconds), for dynamic curing, is required to report curing speed (units are ft / sec) 4. radiation energy, J / cm2 radiation is the radiation energy and time to the product, but also through the various band radiometer to measure received. The test is usually by your customers through the monitoring of the production process to complete, in your report, also includes the parameters of the best. At the very least, you should also be listed in both UVA and UVC radiation energy band.
The following is a correct UV curing conditions set report: Curing:

 UVA - x watts / square cm, z J / cm2

 UVC - y watt / cm2, w J / cm2

 Curing speed: x ft / sec. Testing the use of radiation and irradiation of lamp types are: EIT PowerPuck ® and Fusion D-type lamp answer:

 "200 watts / inch," "10 feet / minute," "gallium lights" - did not give radiosity (Watt / square centimeters), radiation energy (J / cm2), and made no mention of the wavelength (though gallium lamp can give us some tips).

 "25 J / square cm," "mercury" - did not give radiosity (Watt / square centimeters), and made no mention of the wavelength (though mercury can give us some tips), also missed the curing time and speed.

 "7 seconds" - need to increase the radiation degrees (Watt / cm2) and the wavelength. This parameter indicates that this is a static curing process and therefore need to be radiation radiation energy and time to measure the product.

 "120 watts / cm, H-type tubes" - did not give radiosity (Watt / square centimeters), energy (J / cm2) and wavelength (although H-lamp can give us some tips), curing time and speed. □ training regardless of your company big or small, or just involved in the design of the field of UV curing formula or recipe for many years design experience, QC that you can develop training programs to meet your special requirements. Training can be in your company, but also can come to QC's office. Some companies have a new division or new chemical technician at the upcoming posts, we need to in their company's internal meeting on their training, such as sales meetings or new product development meeting. These we can do, training topics such as: equipment maintenance, troubleshooting, radiometry, formulation design, effective UV curing formulation design.

author: Chenbro electronic      Published at: 2008-6-19 2:08:22